50 Fetal Simulator
Ordering information
PS320 Fetal Simulator
MFH-1 Mechanical Fetal Heart Probe
(includes fetal heart cable 17156)
Kit #1: GE Corometrics
PS320 KIT GE CORO PS320 Fetal
Monitoring Kit, GE Corometrics,
includes:
PS320 Fetal Simulator (includes
Operator Manual (MANUAL), Battery
Eliminator (BE-UNVSL-IEC320C14), 9 V
Battery)
MFH-1 Mechanical Fetal Heart Probe
[includes Fetal Heart Cable (17156)]
ACCU LUNG CASE Soft-Sided Carrying
Case
17291 RS-232 Cable, PS320/420
17483 Corometrics Ultrasound
Simulation Cable
17481 Corometrics IUP Cable
17486 Corometrics TOCO Simulation
Cable
4021537 Corometrics 120 Ultrasound
Cable
Kit #2: Hewlett-Packard, Agilent,
Philips Medical
PS320 KIT PHILIPS PS320 Fetal
Monitoring Kit, Series 50/8040 Philips
Medical, Hewlett-Packard, Agilent,
includes:
PS320 Fetal Simulator (includes
Operator Manual (MANUAL), Battery
Eliminator (BE-UNVSL-IEC320C14), 9 V
Battery)
MFH-1 Mechanical Fetal Heart Probe
[includes Fetal Heart Cable (17156)]
ACCU LUNG CASE Soft-Sided Carrying
Case
17291 RS-232 Cable, PS320/420
17482 HP/AG/PHILIPS (50 Series)
Ultrasound Simulation Cable PS320
17484 HP/AG/PHILIPS (50 Series) EXT
TOCO Simulation Cable PS320
2462528 Agilent 50/8040 Series IUP
17488 HP (8040 Series) Ultrasound
Simulation Cable PS320
17489 HP (8040 Series) EXT TOCO
Simulation Cable PS320
Kit #3: Oxford Medical
PS320 KIT OXFORD PS320 Fetal
Monitoring Kit, Oxford Medical,
includes:
PS320 Fetal Simulator (includes
Operator Manual (MANUAL), Battery
Eliminator (BE-UNVSL-IEC320C14), 9 V
Battery)
MFH-1 Mechanical Fetal Heart Probe
[includes Fetal Heart Cable (17156)]
ACCU LUNG CASE Soft-Sided Carrying
Case
17291 RS-232 Cable, PS320/420
17492 Oxford IUP Cable PS320
17491 Oxford Ultrasound Simulation
Cable 2 MHz (blue) PS320
17490 Oxford Ultrasound Simulation
Cable 1.5 MHz (yellow) PS320
Fetal ECG (continued)
Variability selections
(added to fetal ECG)
Absent variability, low variability, mild variability, high
variability severe variability, long-term variability
Note: These patterns repeat and toco channel will perform toco wave
selected.
Optional mechanical
heart
Provides a mechanical interface to the ultrasound trans-
ducer; can be connected to either ultrasound channels.
This option, due to its power consumption, requires an
ac adapter to be connected.
Maternal ECG ECG static rates: 60 BPM, 80 BPM, 100 BPM, 120 BPM,
140 BPM, and 160 BPM
ECG sensitivity: 0.5 mV, 1 mV, and 2 mV
Pattern selected during Trend #1 selection
Uterine activity
Note: Toco waveform selection
not available during Trend #1.
Execute waveform: Start toco waveform
Uterine wave Off: Stop toco waveform
Analog 0 V TO 1 V: Analog range 0 V to 1 V
(1 V = 100 mmHg)
Uterine wave 0 to 25: Range of toco waveform
Uterine wave 0 to 50: Range of toco waveform
Uterine wave 0 to 100: Range of toco waveform
Short duration: Toco waveform of short duration
Normal duration: Normal duration of toco waveform
Increased duration: Long duration of toco waveform
Uterine level = Zero: Zero toco channel
(automatic on power up)
Uterine static +20: Increase toco static level by
20 mmHg
(0 mmHg to 100 mmHg)
Incr. resting tone: Resting tone increases
Couping: 2 close toco waves
Tripling: 3 close toco waves
Uterine pressure sensitivity: 5 µV or 40 µV on power up
Important notes
US-1 tracks the fetal ECG rates
US-2 is the second ultrasound channel with a normal
fetal ECG pattern
On the fetal and maternal ECG, the fetal ECG is 1/4
the size of the maternal ECG
The PS320 turns on in
the following state:
Fetal ECG static rate @ 150 BPM
US-1 tracks @ 150 BPM
US-2 normal pattern
Pressure sensitivity @ 5 µV/mmHg
Pressure/Toco set to zero
Maternal ECG rate @ 80 BPM
ECG sensitivity @ 1 mV
Toco wave is normal duration @ 0 to 50 divisions
(i.e. 0 mmHg to 50 mmHg)
Temperature
Operating 15 °C to 35 °C (59 °F to 95 °F)
Storage 0 °C to 50 °C (32 °F to 122 °F)
General information
Display 2-line x 16-character LCD with keypad
RS-232 Bidirectional interface, 9600 baud
Power 9 V battery/battery eliminator; low battery indication
set at 6 V
Housing Plastic case
Dimensions 15.6 cm x 9.4 cm x 3.4 cm (6.1 in x 3.7 in x 1.3 in)
Weight 0.4 kg (0.9 lb)
PS320
Fetal Simulator
Specications
riešenia na presné meranie